Wacker Neuson
IRFU30/120/5 UK · IRFU internal vibrators
Vibration data and trigger-time calculator
Calculate this tool’s exposure
Other tools in your current tab’s daily draft are kept when you add this tool. Review the combined daily total in the calculator.
Time and points at your selected magnitude
Times assume no other exposure that day and are rounded down to whole minutes. These thresholds are not safe-time allowances. Keep exposure as low as reasonably practicable.
Manufacturer declarations
Wacker Neuson IRFU manual 5000212651 · 05/2018 v18 · item 5000610101 · reviewed 18 September 2026 · Exact UK 110–130 V model and hose length checked. EN ISO 20643 declaration; manual footnote states operation freely suspended in air at 1 m distance. This is a laboratory declaration, not a measurement at the operator’s grip in concrete. Earlier manual figures used a different test setup and are not substituted here. · Match your exact model, generation, attachment and working mode.
| Working mode | Declared m/s² | Uncertainty K m/s² |
|---|---|---|
| Internal vibration · manufacturer free-air test at 1 m | < 2.5 | 0.5 |
Declarations are test results, not workplace measurements. The catalogue starting value is the manufacturer declaration plus published K when K is above 1.5 m/s². Otherwise a 1.5 m/s² allowance is used, including when K is missing. This minimum allowance is a site default; the actual manufacturer K remains in the table above. No HSE tool-type minimum is applied. Missing declarations require an assessed value. Match the working mode, battery and accessory to the manufacturer source. Use your employer’s assessed value where appropriate.
Current and historical sources are included; catalogue coverage and UK sales status are not fully verified. Missing or ambiguous figures require assessment.
HSE calculation and threshold guidance ↗