Time and points at your selected magnitude
Times assume no other exposure that day and are rounded down to whole minutes. These thresholds are not safe-time allowances. Keep exposure as low as reasonably practicable.
Manufacturer declarations
Manufacturer manual review · 18 September 2026 · PDF page references in each working mode · Combination-specific declarations from the FS-KM and, where listed, FCS-KM manuals. Select the exact attachment; this is not a universal powerhead figure. Higher handle used, K 2.0. Dutch manual: maaikop = mowing head; metalen maaigarnituur = metal cutting attachment. · Match your exact model, generation, attachment and working mode.
| Working mode | Declared m/s² | Uncertainty K m/s² |
|---|---|---|
| Select your exact powerhead + attachment combination | Value required | Not available |
| KMA 80.0 R loop + FS-KM mowing head · IEC 62841-4-4 · left 5, right 2.7 m/s²; higher handle | 5 | 2 |
| KMA 80.0 R loop + FS-KM metal cutting attachment · IEC 62841-4-4 · left 3.8, right 2.4 m/s²; higher handle | 3.8 | 2 |
| FCS-KM + KMA 80.0 R loop · EN 20643 · left 2.9, right 1.9 m/s²; higher handle | 2.9 | 2 |
Declarations are test results, not workplace measurements. The catalogue starting value is the manufacturer declaration plus published K when K is above 1.5 m/s². Otherwise a 1.5 m/s² allowance is used, including when K is missing. This minimum allowance is a site default; the actual manufacturer K remains in the table above. No HSE tool-type minimum is applied. Missing declarations require an assessed value. Match the working mode, battery and accessory to the manufacturer source. Use your employer’s assessed value where appropriate.
Current and historical sources are included; catalogue coverage and UK sales status are not fully verified. Missing or ambiguous figures require assessment.
HSE calculation and threshold guidance ↗